2020-08-03; 12:39:00 EDT
Member Since
2019-04-26
Posts: 91
Roger, I think you are saying that I can conceivably calculate the shear force that the screws need to withstand. All of my analysis and comments up to this point have been about pullout force, not shear. I have been assuming that the shear forces acting on the three screws are trivial relative to the strength of the screw, the tabernacle base and the mounting block. Perhaps this is a mistake and this force is not trivial. Now in thinking about it for the first time, if there is a non-structural gap between the bottom of the tabernacle base and the epoxy plug (maybe 1/4") that is filled with gelcoat or some other sealant, this gap would effectively transfer the lateral shear force into a rotational force on the screw, a component of which would be pullout force and could be calculated. Thanks, Chris ----- Long Beach Island -- Sent from: http://rhodes-22.1065344.n5.nabble.com/See the original archive post