The Rhodes 22 Discussion Group R22 Discussion Group

The Rhodes 22 Discussion Group


< prior

Back to Month

Go to Thread

Member Picture

Graham Stewart



Hull Thickness

2021-10-05; 08:14:42 EDT

Member Since

2005-04-29

Posts: 814

If fastening the pump to the bilge floor is the issue another alternative to using 5200 on the pump directly would be to epoxy a piece of plywood to the bilge and screw the pump to the plywood. The plywood pad should be totally encapsulated in the epoxy so that it doesn't rot. The advantage of using the plywood is that you can remove the pump by removing the screws. It might not be possible to remove the pump without destroying it if you use 5200 directly. The disadvantage of using a plywood pad is that the pump will be off the hull by the thickness of the plywood and therefore not drain as well.

Graham Stewart
Agile, Rodes 22, 1976
Kingston Ontario







See the original archive post
×